R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

  • 1
  • 2
  • 3

Brand Name : COOLNET

Model Number : CR, XR012A, XR023A

Certification : CE,ISO

Place of Origin : CHINA

MOQ : 1set

Price : 1800-30000USD

Payment Terms : T/T, L/C

Supply Ability : 300 PCS PER MONTG

Delivery Time : 10-25 working days

Packaging Details : Packed in plywooden case, standard export package

Name : In-Row Air Conditioning Units

Product Application : Data Center, Modular Data Center,Container Data Center

Product Type : Row Based Precision Air Cooling System

Mounting : Floor Standing

Warranty : 1 Year

Voltage : 380/400 VAC,230 VAC,220V

Cooling Capacity : 12-40KW

Refrigerant : R410A/ R407C

Fan Type : Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan

Color : Black,Grey,White, Other colors

Contact Now

In-Row Air Conditioner Units For Partially Over-Heated Server Rooms 5000 M3/H

Product Introduction

The electronic equipment in the server rooms usually emits a lot of heat during operation. And if too many electronic devices are placed in the computer room of a data center, it will cause local heat accumulation and fail to effectively dissipate heat. Furthermore, the life of the electronic equipment is lost, and even circuit failure is caused. Therefore, a reasonable and efficient heat dissipation device is urgently needed in the computer room.

According to this situation, Coolnet power designed the Cool-row series of in-row air conditioners. This air conditioners can completely solve the problem of short-circuit of cold and hot air flow through the horizontal air supply method of supplying air from the cold aisle and then returning the air from the hot aisle, ensuring the uniform temperature of the server cabinet, eliminating local hot spots, and increasing the number of servers. The reliability of the operation at the same time effectively reduces unnecessary energy consumption.

Feature & Benefits

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

Applications

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H
  • Data center with single rack above 3kW
  • High heat density computer room
  • Partially overheated computer room
  • Modular DC
  • Container DC
  • Low PUE data center
  • Renovation of local hot spots in the computer room

Advantages

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

EVO Control System

  • Graphic display, including the running status and the temperature/humidity of the inlet/outlet air
  • Advanced team work function, up to 32 units and easy to set network
  • Standard RS485 port, optional SNMP, TCP/IP interfaces, and GPRS with SMS
  • Standard communication protocol, optional customized specifications
  • Electronically Commutated Compressor

R410A

  • Compressor speed is infinitely variable dependent on the heat load
  • Energy saving under partial-load mode, improving energy efficiency
  • Significant reduce the start/stop frequency of the compressor
  • Improve the system reliability

Options

  • Transfer switch for Dual Power Input
  • Baffles
  • Low-temperature startup kits
  • GPRS SMS alarm
  • Wired temperature/humidity sensors
  • Three-way water valve

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

Factory Details

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

Packing and Delivery

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

Case

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H


Product Tags:

12KW In Row Air Conditioner

      

5000 M3/H In Row Air Conditioner

      

R410A Server Room Air Conditioner

      
Wholesale R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H from china suppliers

R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0